MODEL PBA50F-3R3 PBA50F-5 PBA50F-9 PBA50F-12 PBA50F-15 PBA50F-24 PBA50F-36 PBA50F-48
MAX OUTPUT WATTAGE[W] 33 50 50.4 51.6 52.5 52.8 50.4 52.8
DC OUTPUT 3.3V 10A 5V 10A 9V 5.6A 12V 4.3A 15V 3.5A 24V 2.2A 36V 1.4A 48V 1.1A
SPECIFICATIONS
MODEL PBA50F-3R3 PBA50F-5 PBA50F-9 PBA50F-12 PBA50F-15 PBA50F-24 PBA50F-36 PBA50F-48
INPUT
VOLTAGE[V] AC85 - 264 1
f
or DC120 - 370
(
AC50 or DC70 optionally available
*
4
)
CURRENT[A]
ACIN 100V
0.5typ 0.7typ
ACIN 200V
0.3typ 0.4typ
FREQUENCY[Hz] 50/60
(
47-63
)
EFFICIENCY[%]
ACIN 100V
75typ 80typ 79typ 80typ 81typ 82typ 83typ 83typ
ACIN 200V
76typ 82typ 81typ 82typ 83typ 84typ 85typ 85typ
POWER FACTOR
(
Io=100%
)
ACIN 100V
0.98typ 0.99typ
ACIN 200V
0.87typ 0.93typ
INRUSH CURRENT[A]
ACIN 100V
15typ
(
Io=100%
)(
At cold start
)
ACIN 200V
30typ
(
Io=100%
)(
At cold start
)
LEAKAGE CURRENT[mA] 0.4/0.75max
(
ACIN 100V/240V 60Hz
,
Io=100%
,
According to IEC60950-1
)
OUTPUT
VOLTAGE[V] 3.3 5 9 12 15 24 36 48
CURRENT[A] 10 10 5.6 4.3 3.5 2.2 1.4 1.1
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max
RIPPLE[mVp-p]
0to+50
C
*
1
80max 80max 120max 120max 120max 120max 150max 150max
-10-0
C
*
1
140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]
0to+50
C
*
1
120max 120max 150max 150max 150max 150max 250max 250max
-10-0
C
*
1
160max 160max 180max 180max 180max 180max 300max 300max
TEMPERATURE REGULATION[mV]
0to+50
C
50max 50max 90max 120max 150max 240max 360max 480max
-10 to +50
C
60max 60max 120max 150max 180max 290max 450max 600max
DRIFT[mV]
*
2
20max 20max 36max 48max 60max 96max 144max 192max
START-UP TIME[ms] 350typ
(
ACIN 100V
,
Io=100%
)
HOLD-UP TIME[ms] 20typ
(
ACIN 100V
,
Io=100%
)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0 - 53.0
OUTPUT VOLTAGE SETTING[V]
3.20 - 3.40 4.90 - 5.20 8.70 - 9.30 11.5 - 12.5 14.5 - 15.5 23.5 - 24.5 35.5 - 36.5 47.0 - 49.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0 - 65.0
OPERATING INDICATION LED
(
Green
)
REMOTE ON/OFF Optional
(
Required external power source
)
ISOLATION
INPUT-OUTPUT
-
RC
*
3
AC3
,
000V 1minute
,
Cutoff current = 10mA
,
DC500V 50M
W
min
(
At Room Temperature
)
INPUT-FG AC2
,
000V 1minute
,
Cutoff current = 10mA
,
DC500V 50M
W
min
(
At Room Temperature
)
OUTPUT
-
RC-FG
*
3
AC500V 1minute
,
Cutoff current = 100mA
,
DC500V 50M
W
min
(
At Room Temperature
)
ENVIRONMENT
OPERATING TEMP.
,
HUMID.AND ALTITUDE
-10 to +71
C
(
Required Derating
),
20 - 90%RH
(
Non condensing
)
3
,
000m
(
10
,
000feet
)
max
STORAGE TEMP.
,
HUMID.AND ALTITUDE
-20 to +75
C
,
20 - 90%RH
(
Non condensing
)
3
,
000m
(
10
,
000feet
)
max
VIBRATION 19.6m/s
2
(
2G
),
10 - 55Hz
,
3minutes period
,
60minutes each along X
,
Y and Z axis
IMPACT 196.1m/s
2
(
20G
),
11ms
,
once each X
,
Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1
,
C-UL
(
CSA60950-1
),
EN60950-1
,
EN50178 Complies with DEN-AN
(
At only AC input
)
CONDUCTED NOISE Complies with FCC Part15 classB
,
VCCI-B
,
CISPR22-B
,
EN55011-B
,
EN55022-B
CE MARKING Low Voltage Directive
,
EMC Directive
HARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERS
CASE SIZE/WEIGHT 31
X
82
X
120mm
(
without terminal block
)(
W
X
H
X
D
)
/ 280g max
(
without cover
)
COOLING METHOD Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :
RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.
*4 Derating is required.Consult us for details.
* Parallel operation with other model is not possible.
* Derating is required when operated with cover.
* A sound may occur from power supply at peak loading.
PBA50F
Unit type
PBA 50 F -5 -O
Ordering information
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
(0.15mA max / ACIN 240V)
E :Low leakage current
and EMI class A
(0.5mA max / ACIN 240V)
T :Vertical terminal block
J :Connector type
R :with Remote ON/OFF
N :with Cover
(Only 24V UL508 is acquired)
N1
:with DIN rail
V :Output voltage setting
potentiometer external-
ly
Specification is changed at
option. Please consult us
details.
R
12345
PBA
A-4
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - PBA 50 F -5 -O

MODEL PBA50F-3R3 PBA50F-5 PBA50F-9 PBA50F-12 PBA50F-15 PBA50F-24 PBA50F-36 PBA50F-48MAX OUTPUT WATTAGE[W] 33 50 50.4 51.6 52.5 52.8 50.4 52.8DC OUTPUT

Page 2 - PBA 75 F -5 -O

1 Terminal BlockA-222 FunctionA-232.1 Input voltage range 2.2 Inrush current limiting 2.3 Overcurrent protection 2.4 Overvoltage protection 2.5

Page 3 - PBA 100 F -5 -O

1 Terminal Block1AC (L)2AC (N)3N.C.4Frame Ground5-Output6+Output7LED8Output voltage adjustable potentiometer9CN10CN2 Connector for functionsåCN3* Th

Page 4 - PBA 150 F -5 -O

2.1 Input voltage range¡The range is from AC85 - 264V or DC(Refer to SPECIFICA-TIONS). Only AC input is available to comply with agency approval.¡A

Page 5 - PBA 600 F -5 -O

2.8 Remote sensing(It is not in PBA50F and PBA75F.)¿ PBA100F, 150F¡It corresponds by the option : -K. The correspondence model is -3R3 and -5. Please

Page 6

3 Peak Current4.1 Series operation¡Series operation is possible by connecting as shown in Fig.4.1. Output current in series connection should be low

Page 7 - PBA1000F

Remarks : This product is not good at parallel operation by which the OR diode is not put because the synchronous rectifi cation method is used.¡Values

Page 8 - PBA1500F

5.1 Installation method¡The screw should be inserted up to 6mm max from outside of the power supply to keep a distance between inside parts and an iso

Page 9 - Basic Characteristics Data

6 Others6.1 Output current monitor¿ PBA300F, 600F, 1000F, 1500F¡It is possible to know the output current to measure the voltage between CB to -S in

Page 10 - Instruction Manual

7.1 Option outline¡Consult us detailed option and delivery before hand.¡It is possible a combination of the option, and consult us that it is not pos

Page 11 - 1 Terminal Block

¿-F3 (PBA300F / 600F / 1000F / 1500F)-Reverse air exhaust type.-The difference from standard is shown Fig.7.2 and Fig.7.3.¿-F4 (PBA300F / 600F / 1000F

Page 12 - 2 Function

MODEL PBA75F-3R3 PBA75F-5 PBA75F-9 PBA75F-12 PBA75F-15 PBA75F-24 PBA75F-36 PBA75F-48MAX OUTPUT WATTAGE[W] 49.5 75 75.6 75.6 75 76.8 75.6 76.8DC OUTPUT

Page 13

¿-R (PBA50F / 75F / 100F / 150F)¡Option ”-R” is available for remote ON / OFF.¡When external power source is in the range of 4.5 - 12.5V, current limi

Page 14 - Operation

MODELPBA100F-3R3PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48MAX OUTPUT WATTAGE[W] 66 100 94.5 102 105 108 100.8 100.8DC

Page 15

MODELPBA150F-3R3PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 PBA150F-24 PBA150F-36 PBA150F-48MAX OUTPUT WATTAGE[W] 99 150 150.3 156 150 156 154.8 158.4DC

Page 16 - Installation Method

MODELPBA600F-3R3PBA600F-5PBA600F-7R5PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48MAX OUTPUT WATTAGE[W] 396 600 600 636 645 648 648 624DC OUTP

Page 17 - 6 Others

MODELPBA600F-3R3PBA600F-5PBA600F-7R5PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48MAX OUTPUT WATTAGE[W] 396 600 600 636 645 648 648 624DC OUTP

Page 18 - 7 Option

MODELPBA1000F-3R3PBA1000F-5PBA1000F-7R5PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48MAX OUTPUT WATTAGE[W] 660 1000 1005 1056 1050 1056 1

Page 19

MODELPBA1500F-3R3PBA1500F-5PBA1500F-7R5PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48MAX OUTPUT WATTAGE[W] 990 1500 1500 1500 1500 1680 1

Page 20

Basic Characteristics Data*1 Refer to Series/Parallel Operation of Instruction Manual.* The value of input current is at ACIN 100V and rated load.inpu

Comments to this Manuals

No comments