MODEL
PBA100F-3R3
PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48
MAX OUTPUT WATTAGE[W] 66 100 94.5 102 105 108 100.8 100.8
DC OUTPUT 3.3V 20A 5V 20A 9V 10.5A 12V 8.5A 15V 7A 24V 4.5A 36V 2.8A 48V 2.1A
SPECIFICATIONS
MODEL
PBA100F-3R3
PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48
INPUT
VOLTAGE[V] AC85 - 264 1
f
or DC120 - 370
(
AC50 or DC70 optionally available
*
4
)
CURRENT[A]
ACIN 100V
0.9typ 1.3typ
ACIN 200V
0.5typ 0.7typ
FREQUENCY[Hz] 50/60
(
47-63
)
EFFICIENCY[%]
ACIN 100V
77typ 82typ 80typ 81typ 83typ 84typ 84typ 84typ
ACIN 200V
79typ 84typ 82typ 83typ 86typ 86typ 86typ 86typ
POWER FACTOR
(
Io=100%
)
ACIN 100V
0.98typ 0.99typ
ACIN 200V
0.87typ 0.93typ
INRUSH CURRENT[A]
ACIN 100V
20typ
(
Io=100%
)(
At cold start
)
ACIN 200V
40typ
(
Io=100%
)(
At cold start
)
LEAKAGE CURRENT[mA] 0.4/0.75max
(
ACIN 100V/240V 60Hz
,
Io=100%
,
According to IEC60950-1
)
OUTPUT
VOLTAGE[V] 3.3 5 9 12 15 24 36 48
CURRENT[A] 20 20 10.5 8.5 7 4.5 2.8 2.1
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max
RIPPLE[mVp-p]
0to+50
C
*
1
80max 80max 120max 120max 120max 120max 150max 150max
-10-0
C
*
1
140max 140max 160max 160max 160max 160max 200max 200max
RIPPLE NOISE[mVp-p]
0to+50
C
*
1
120max 120max 150max 150max 150max 150max 250max 250max
-10-0
C
*
1
160max 160max 180max 180max 180max 180max 300max 300max
TEMPERATURE REGULATION[mV]
0to+50
C
50max 50max 90max 120max 150max 240max 360max 480max
-10 to +50
C
60max 60max 120max 150max 180max 290max 450max 600max
DRIFT[mV]
*
2
20max 20max 36max 48max 60max 96max 144max 192max
START-UP TIME[ms] 350typ
(
ACIN 100V
,
Io=100%
)
HOLD-UP TIME[ms] 20typ
(
ACIN 100V
,
Io=100%
)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0 - 53.0
OUTPUT VOLTAGE SETTING[V]
3.20 - 3.40 4.90 - 5.20 8.70 - 9.30 11.5 - 12.5 14.5 - 15.5 23.5 - 24.5 35.5 - 36.5 47.0 - 49.0
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.00 - 5.25 5.75 - 7.00 11.5 - 14.0 15.0 - 18.0 20.0 - 25.0 30.0 - 37.0 43.0 - 50.0 58.0 - 65.0
OPERATING INDICATION LED
(
Green
)
REMOTE SENSING Optional
(
Only -3R3
,
-5 Option -K
)
REMOTE ON/OFF Optional
(
Required external power source
)
ISOLATION
INPUT-OUTPUT
-
RC
*
3
AC3
,
000V 1minute
,
Cutoff current = 10mA
,
DC500V 50M
W
min
(
At Room Temperature
)
INPUT-FG AC2
,
000V 1minute
,
Cutoff current = 10mA
,
DC500V 50M
W
min
(
At Room Temperature
)
OUTPUT
-
RC-FG
*
3
AC500V 1minute
,
Cutoff current = 100mA
,
DC500V 50M
W
min
(
At Room Temperature
)
ENVIRONMENT
OPERATING TEMP.
,
HUMID.AND ALTITUDE
-10 to +71
C
(
Required Derating
),
20 - 90%RH
(
Non condensing
)
3
,
000m
(
10
,
000feet
)
max
STORAGE TEMP.
,
HUMID.AND ALTITUDE
-20 to +75
C
,
20 - 90%RH
(
Non condensing
)
3
,
000m
(
10
,
000feet
)
max
VIBRATION 19.6m/s
2
(
2G
),
10 - 55Hz
,
3minutes period
,
60minutes each along X
,
Y and Z axis
IMPACT 196.1m/s
2
(
20G
),
11ms
,
once each X
,
Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1
,
C-UL
(
CSA60950-1
),
EN60950-1
,
EN50178 Complies with DEN-AN
(
At only AC input
)
CONDUCTED NOISE Complies with FCC Part15 classB
,
VCCI-B
,
CISPR22-B
,
EN55011-B
,
EN55022-B
CE MARKING Low Voltage Directive
,
EMC Directive
HARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERS
CASE SIZE/WEIGHT 32
X
93
X
147mm
(
without terminal block
)(
W
X
H
X
D
)
/ 440g max
(
without cover
)
COOLING METHOD Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :
RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.
*4 Derating is required.Consult us for details.
* Parallel operation with other model is not possible.
* Derating is required when operated with cover.
* A sound may occur from power supply at peak loading.
PBA100F
Unit type
PBA 100 F -5 -O
Ordering information
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
(0.15mA max / ACIN 240V)
E :Low leakage current
and EMI class A
(0.5mA max / ACIN 240V)
T :Vertical terminal block
J :Connector type
(Only -12,-15,-24,-36,-48)
R :with Remote ON/OFF
N :with Cover
(Only 24V UL508 is acquired)
N1
:with DIN rail
V :Output voltage setting
potentiometer external-
ly
R
12345
PBA
A-8
Specification is changed at
option. Please consult us
details.
Page view 2