Cosel PBA50F Specifications Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
MODEL
PBA600F-3R3
PBA600F-5
PBA600F-7R5
PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48
MAX OUTPUT WATTAGE[W] 396 600 600 636 645 648 648 624
DC OUTPUT
ACIN 100V
3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27A 36V 18A 48V 13A
ACIN 200V
*
3
3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27
(
31
)
A 36V 18A 48V 13A
SPECIFICATIONS
MODEL
PBA600F-3R3
PBA600F-5
PBA600F-7R5
PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48
INPUT
VOLTAGE[V] AC85 - 264 1
f
or DC120 - 350
(
AC50 or DC70 optionally available
*
5
)
CURRENT[A]
ACIN 100V
5.8typ 8.2typ
ACIN 200V
3typ 4.1typ
FREQUENCY[Hz] 50/60
(
47-63
)
EFFICIENCY[%]
ACIN 100V
70typ 75typ 76typ 79typ 79typ 81typ 82typ 81typ
ACIN 200V
72typ 77typ 79typ 82typ 82typ 84typ 84typ 83typ
POWER FACTOR
ACIN 100V
0.98typ
(
Io=100%
)
ACIN 200V
0.95typ
(
Io=100%
)
INRUSH CURRENT[A]
ACIN 100V
20/40typ
(
Io=100%
)(
Primary inrush current /Secondary inrush current
)(
More than 3 sec. to re-start
)
ACIN 200V
40/40typ
(
Io=100%
)(
Primary inrush current /Secondary inrush current
)(
More than 3 sec. to re-start
)
LEAKAGE CURRENT[mA] 0.45/0.75max
(
ACIN 100V/240V 60Hz
,
Io=100%
,
According to IEC60950-1
)
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48
CURRENT[A]
ACIN 100V
120 120 80 53 43 27 18 13
ACIN 200V
*
3
120 120 80 53 43 27
(
31
)
18 13
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]
0to+50
C
*
1
80max 80max 120max 120max 120max 120max 150max 150max
-20-0
C
*
1
140max 140max 160max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]
0to+50
C
*
1
120max 120max 150max 150max 150max 150max 200max 200max
-20-0
C
*
1
160max 160max 180max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]
0to+50
C
*
1
40max 50max 75max 120max 150max 240max 360max 480max
-20to+50
C
*
1
60max 75max 120max 180max 180max 290max 440max 600max
DRIFT[mV]
*
2
12max 20max 30max 48max 60max 96max 144max 192max
START-UP TIME[ms]
400typ
(
ACIN 100/200V
,
Io=100%
)
Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms] 20typ
(
ACIN 100/200V
,
Io=100%
)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
*
4
Vo+0.66 - 1.32
Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0
OPERATING INDICATION LED
(
Green
)
REMOTE SENSING Provided
REMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT
-
RC AC3
,
000V 1minute
,
Cutoff current = 10mA
,
DC500V 50M
W
min
(
At Room Temperature
)
INPUT-FG AC2
,
000V 1minute
,
Cutoff current = 10mA
,
DC500V 50M
W
min
(
At Room Temperature
)
OUTPUT
-
RC
-
AUX-FG AC500V 1minute
,
Cutoff current = 100mA
,
DC500V 50M
W
min
(
At Room Temperature
)
OUTPUT-RC
-
AUX AC100V 1minute
,
Cutoff current = 100mA
,
DC100V 50M
W
min
(
At Room Temperature
)
ENVIRONMENT
OPERATING TEMP.
,
HUMID.AND ALTITUDE
-20 to +71
C
,
20 - 90%RH
(
Non condensing
)
3
,
000m
(
10
,
000feet
)
max
STORAGE TEMP.
,
HUMID.AND ALTITUDE
-20 to +75
C
,
20 - 90%RH
(
Non condensing
)
3
,
000m
(
10
,
000feet
)
max
VIBRATION 19.6m/s
2
(
2G
),
10 - 55Hz
,
3minutes period
,
60minutes each along X
,
Y and Z axis
IMPACT 196.1m/s
2
(
20G
),
11ms
,
once each X
,
Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1
,
C-UL
(
CSA60950-1
),
EN60950-1
,
EN50178 Complies with DEN-AN
(
At only AC input
)
CONDUCTED NOISE Complies with FCC Part15 classB
,
VCCI-B
,
CISPR22-B
,
EN55011-B
,
EN55022-B
CE MARKING Low Voltage Directive
,
EMC Directive
HARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERS
CASE SIZE/WEIGHT 120
X
61
X
190mm
(
without terminal block and screw
)(
W
X
H
X
D
)
/1.6kg max
COOLING METHOD Forced cooling
(
internal fan
)
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail.
*4 Overvoltage protection circuit to follow to output voltage setting.
*5 Derating is required.Consult us for details.
* A sound may occur from power supply at pulse loading.
PBA600F
Unit type
PBA 600 F -5 -O
Ordering information
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F1
:With Long-Life fan
F3
:Reverse air exhaust
type
F4
:Low speed fan
R
12345
PBA
A-14
Refer to instruction manual
7.1
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 19 20